The salient features of the Classic Line implants are the following: perfectly cylindrical shape, with a rounded apex in order to prevent the risk of damaging the anatomical structures during the insertion phase (for example: the Schneiderian membrane) and with longitudinal self-tapping cuttings; the 0.5 mm machined collar designed in order to minimise the risk of peri-implantitis occurrence; the single start external thread, with Micro and Normo pitch.
The connection type is internal hexagonal, with mini and standard dimensions and platforms to which is added the specific Maxi platform for posterior areas that require greater prosthetics. The consequence of this choice is a prosthetic range, with multiple possibilities of choice for the Implantologist depending on the different anatomical situations to deal with.
This variety is also increased by the fact that the core of Classic implants is perfectly corresponding to that of the Piesse and PSK implants: a single surgical kit allows the insertion of the three Lines, giving the Professional the opportunity to have many combinations of use.
micro thread
normo thread
Diameter and Lengths
MICRO ThreadMini platform |
NORMO ThreadStandard platform |
Surface Treatment AMS (Advanced Micro Surface)
AMS (Advanced Micro Surface), the surface selected for all the implants of OXY Implant system, is obtained with processes of etching, decontamination and treatment with Argon plasma at cold, which combined, give rise to a high degree of cleanliness surface, characterized by a homogeneous microporosity with the distance between the peaks of a few microns (see the following X5000 and X7500 images) and therefore capable of increasing the adhesion of osteoblasts and consequently encourage the osteogenesis process.
OXY CLAMP Package System
All the implants of the OXY Implant line are contained in a plastic tube sealed by a screw cap with safety ring, tested to guarantee sterility for 5 years. Sterilization is performed by irradiation with beta rays. | ||||
MOUNT FREE - OXY CLAMP SYSTEM: • implant and cover screw are placed in a plastic support with a titanium core • it allows to see implant and cover screw before opening the sterile tube and prevents implant movements for an easier extraction |
||||
Implant extraction in 5 simple steps: |
||||
Prosthetic Components
Healing screw Impression coping transfer for open and closed tray Laboratory analogue Temporary abutment rotational and antirational Straight abutment Milling abutment straight antirotational Angled abutment 15° and 25° antirational Castable abutment rotational and antirational Ball abutment screw-retained |
Oxy Loc abutment Aesthetic abutment Universal base screw-retained Titanium and Cobalt-Chrome base Pre-milled abutment antirotational Anatomical abutment straight screw-retained Scan Body intraoral and model scanning Digital analogue Cad-Cam |
Prosthetic Components for Immediate Loading
ILS (Immediate Load System) includes all of the components that, in a safe and reliable way, allow a fast prosthetic rehabilitation thanks to the use of immediate loading technique. To this purpose, straight and angled bases are available to match a titanium temporary abutment, a cover for bonding or a castable abutment.
Healing cap for ILS base Impression coping transfer for ILS base Laboratory analogue for ILS base Straight base ILS Angled base 17° ILS Angled base 35° ILS Castable for ILS base Temporary for ILS base Scan Body intraoral and model scanning for ILS base Cover for bonding and for fusion for ILS base Digital analogue for ILS base |
Surgical Instruments
All surgical instruments are designed and manufactured with the purpose to ensure their durability. This prerogative is achieved first of all thanks to the use of absolute quality raw materials. The production cycle is then consistently completed by finishing processes of last generation: for example, the most subject to wear devices are treated with Black Diamond coating (mechanical instruments) and Gold Titanium (manual) which guarantee higher surface hardness and wear resistance. The Classic line drills are graduated with laser markings that indicate the length of the implants. For the same purpose, they can also be provided with depth stoppers. Their morphology is cylindrical with a smaller diameter apical portion to provide a surgical site that closely follows the shape of the implant. The Black Diamond coating increases the cutting power, thereby reducing the bone heating and the wear of the drill. The torque ratchet (10-70 Ncm) completes the surgical equipment, totally made in the workshop of OXY Implant, with circular head of size corresponding to that of the driver which equips the screwdrivers and the manual inserters. In this way it is possible to realise the prosthetic components tightening with controlled torque and the final insertion of the implant when the force developed by the motor system is not sufficient. |
SURGICAL KITThe Oxy Implant surgical kits are designed with the purpose to encourage the compactness of size and ease of use. The arrangement of the instruments and the colour coding that characterises them determines a logical and intuitive way of use during the successive steps of the intervention. To facilitate their maintaining, the boxes are made of autoclavable and autosanitising plastic. |